Booting from the external storage array
45
Installation and Configuration
The order of the HBA instances listed is the order in which they
have been enumerated by the system. This does not necessarily
correspond to PCI slot numbering. In this example, the two
QLogic HBAs installed in the server are using driver handles 5F
and 60, respectively.
a. Type
drvcfg.
b. Press Enter.
Figure 28 Driver handle numbers
12. Find the driver handle numbers that correspond to those listed
for the QLogic HBAs (as shown in Figure 28). Note the two digits
(proceeded by Ctrl, as shown in Figure 28) next to the driver
handles for the QLogic HBAs. These are control handles.
13. Determine the HBA instance that will be used for boot, and enter
the QLogic Fibre Channel Driver Configuration Utility by
typing drvcfg -s <driver handle> <control handle> (where
driver handle and control handle are the values that correspond
to the HBA instance to be used for boot. In this example, "
drvcfg
-s 5f 62
" is used.)
14. Press Enter.
The Fibre Channel Driver Configuration Utiliity menu will be
displayed (as shown in Figure 29 on page 46).