Troubleshooting
Known issues
Be aware of these issues:
QLogic BIOS 1.26 and later for QLA23xx and BIOS 1.79 and later
for QLA22xx HBAs allow for multiple Boot Port Name entries to
be configured for high-availability booting after path failures.
Previous BIOS versions do not support this functionality, will
boot only from a single storage array port, and cannot provide
boot capability with path failures.
NTOSKNL BSOD (blue screen) during a link-down event can
cause file system corruption to mounted file systems.
HBA boot BIOS does not support high availability while the OS is
booting. It can handle path failures at boot initialization time, and
after the OS has loaded. Path failures while the OS is loading will
require the host to reboot before successfully completing the boot
process.
Degraded response time as the I/O load approaches storage
system capacity can make the OS appear hung or result in a
NTOSKNL BSOD.
Boot files, Windows system files, and swap space should all be on
the boot LUN. With certain server models, you can use an internal
disk for the page file for stability; however, this might not
increase fault tolerance and might reduce system recovery
options.
Swap space must be available on %SYSTEMROOT% or core dump
will fail.
For Windows 2003 on 64-bit IA64-2 servers, the system no longer
uses an x86-compatible BIOS; therefore, enabling boot-from-array
support with the HBA requires a separate firmware EFI
download.
For servers booting from the array, a Symmetrix out-of-family
microcode load, or a CLARiiON Flare NDU between versions
will cause the server to require a reboot. This occurs because
Windows requires a reboot when characteristics of the boot LUN
change. During the NDU process on EMC storage arrays, the
serial number and inquiry VPD data will change to reflect the
new code version. When Windows performs a rescan and
recognizes this change, it assumes a change has occurred on the
boot LUN and will require a reboot.