70
Configuring a Boot Device on an EMC Storage Array
• If there are multiple QLogic HBAs, a list of addresses occupied
by those HBAs appears. Since the EMC storage array is
attached to the lowest-numbered PCI slot, select the first
adapter from the list; then press Enter. The Fast!UTIL Options
menu appears.
4. From the Fast!UTIL Options menu, select Configuration
Settings and press Enter..
5. From the Configuration Settings menu, select Adapter Settings
and press Enter..
6. From the Host Adapter Settings menu, select Host Adapter
BIOS and press Enter. to enable it if it is not already enabled.
Note: Refer to the Table 1 on page 21 for recommended settings.
7. Press ESC to exit the Configuration Settings menu.
8. From the Configuration Settings menu, select Selectable Boot
Settings and press Enter..
9. From the Selectable Boot Settings menu, select Selectable Boot
Device and press Enter. to enable this option if it is not already
enabled.
10. Select Current Boot Node Name and press Enter..
The adapter will scan for attached storage devices which will be
displayed on the screen.
Note: Depending upon the CLARiiON array model, the HBA may not
yet detect any LUNs or it may detect a LUNZ labeled device. This
behavior is acceptable and to be expected.
11. Skip from the BIOS configuration to a separate host that has
Navisphere Management software installed and is attached to the
CLARiiON Storage Array.
Since the operating system is not yet installed, the Naviagent/CLI
is not running on the Linux host. Therefore, the HBA may need
to be registered manually.
From the management host, manually register the host's HBA
and add the host to the newly created Storage Group using
Navisphere Management software.
12. Return to the BIOS configuration and reboot the host.