EMC Fibre Channel and iSCSI with QLogic Host Bus Adapters in the Windows Environment
Miscellaneous Planning and Procedures
Special instructions for the EMC CLARiiON CX200 series
This section contains the following information:
“Set the HBA FC-AL loop ID” on page 128
“Direct-connect dual-host clustering configurations” on page 130
Set the HBA FC-AL loop ID
While configuring a QLA234x HBA for Windows 2000 and
connection to CLARiiON CX200 series for direct-connect cluster
configurations, you must manually set the HBA FC-AL Loop ID.
Follow these steps to enable loop hard addressing and set the loop ID
on each HBA:
Perform this procedure on all nodes in the cluster connected to the CX200
series array.
1. Boot the Windows host; press Ctrl-Q when prompted to Press
<CTRL-Q> for Fast!UTIL. (This prompt appears with the QLogic
startup banner.)
2. After the Fast!UTIL program loads, the initial display depends on
whether there are multiple QLogic HBAs installed in the server:
If there is only one QLogic HBA, the Fast!UTIL Options menu
appears.
If there are multiple QLogic HBAs, a list of memory addresses
occupied by those HBAs appears.
Using the arrow keys, select the desired HBA and press
ENTER.
The Fast!UTIL Options menu appears.
3. Select Configuration Settings from the Fast!UTIL Options menu,
and press Enter.
4. Select Host Adapter Settings from the Configuration Settings
menu.
5. Select Adapter Hard Loop ID from the Host Adapter Settings
menu and press
ENTER until the value is Enabled.
6. Select Hard Loop ID and press Enter.