Technical notes
EMC AX150-Series Integrated Management Software Release Notes
Technical notes
This section contains information that will help with the installation, use,
and management of the storage system. It provides generic information
that applies to all platforms as well as platform-specific information.
AX150SC, AX150SCi, AX150, and AX150i notes
SP startup
For dual-SP storage systems (AX150 or AX150i), EMC recommends that
you reboot an SP only during periods of low I/O activity. If the server
does not have at least one path to each SP, we recommend stopping
server I/O. For a single-SP storage system (AX150SC or AX150SCi), stop
all I/O to the storage system.
Returning a storage system to an uninitialized state
To return an AX150 storage system to the uninitialized state (no
management passwords, able to change management IP addresses) go to
the AX150 support website and choose Get Service & Support >
Frequently Asked Questions.
Event log entries appear out of order
FLARE OE software may not always enter items into the event log in the
order in which they occurred. This happens only when several events
occur at approximately the same time. The time stamps are correct.
Hot spare ownership
Once a hot spare is assigned to a degraded virtual disk, that virtual disk
owns it until either the virtual disk is repaired and the equalize
operation completes, or the virtual disk is destroyed. If the virtual disk is
accidentally double-faulted because you removed the wrong disk
module during repair, then re-inserting the incorrectly removed disk
module should cause the virtual disk to return to its original state
(including continued operation with the hot spare engaged).
Disk module insertion and removal
When inserting or removing more than one disk module from a storage
system, you must pause between each removal or insertion to allow the
storage system to recover. Before inserting or removing the next disk
module you should make sure that:
A newly inserted disk module's amber light is off and its blue light
has returned to a normal state: on or blinking due to I/O in progress.