Fixed problems
EMC AX150-Series Integrated Management Software Release Notes
Problem Details
Navisphere Express would not save the user’s
selection to not send email events in the selected
language. After a reboot, the option would be
selected again.
Frequency: Always under a specific set of
circumstances.
[156172]
Navisphere Express now saves the user’s selection so that
it persists through a reboot of the SP.
Navisphere Express problems fixed in version 02.20.150.5.019
Problem Details
An invalid check occurs on the Virtual Disk page
that causes the page to display Unknown
error has occurred while
displaying this page."
Frequency: Infrequently under a specific set of
circumstances
[138004, 144979]
Navisphere Express now checks to see if the data returned
from the server is valid before attempting to perform
operations on it.
Memory leaks may cause Navisphere Express to
hit its memory threshold and restart.
Frequency: Always under a specific set of
circumstances.
[140196, 141412]
The memory leaks have been fixed.
Navisphere Server Utility problems fixed in version 6.20.2.0.0
Problem Details
The Japanese version of the Windows Server
Utility will fail for any snapshot operation.
Frequency: Always under a specific set of
circumstances.
[154651]
The default naming scheme allowed a localized string so
comparison was not being done correctly. Navisphere
Express no longer allows the default names to be localized
so that all string comparisons now correctly find a match and
the snapshot operations now succeed.